Default.asp?T_MRI_DOC_LISTOrder=Sorter_list_status&T_MRI_DOC_LISTDir=ASC&T_MRI_DOC_LISTPage=13
 mri_brain_scan
 Default.asp
 GenPg.asp?pgname=Disclaimer
 TheList_search.asp
 SafetyInfog.asp
 GenPg.asp?pgname=ScreeningForm
 GenPg.asp?pgname=ProductTesting
 GenPg.asp?pgname=OrderingBooks
 GenPg.asp?pgname=Lectures
 GenPg.asp?pgname=AboutDrShellock
 PriorityEmail.asp
 
 mri_brain_scan
 

Search THE LIST.   All parameters below are optional.  Click Search button.



     ALL (default) means search results will contain *ALL* words you type above.
                       Selecting ANY returns records having *ANY* words above. (more recs returned) 
   Result Status
Clear Search Fields Click Here for the Info and Terminology Page Regarding THE LIST    
Records: 4844                              Click Here for Search HELP  
Per page:   First Prev   9 10 11 12 13 14 15 16 17 18 of  162  Next Last                                    
Object Status Ascending Strength Reference Safety Info
Inflow
15 x 3.0 mm
316L SS
vInflow Dynamics
Munich, Germany 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Inflow Gold
9 x 3.0 mm
316L SS, gold plate
coil, stent, filter
Inflow Dynamics
Munich, Germany 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Inflow Gold
15 x 3.0 mm
316L SS, gold plate
coil, stent, filter
Inflow Dynamics
Munich, Germany 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Inflow Stent
316L SS
coil, stent, filter
Inflow Dynamics
Munich, Germany 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
IntraCoil Bronchial Endoprosthesis
nitinol
coil, stent, filter
Intratherapeutics, Inc.
St. Paul, MN 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
IntraStent Biliary Endoprosthesis
coil, stent, filter
Intratherapeutics, Inc.
St. Paul, MN 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
IntraStent DoubleStrut Biliary Endoprosthesis
coil, stent, filter
Intratherapeutics, Inc.
St. Paul, MN 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
IntraStent LP Biliary Endoprosthesis
coil, stent, filter
Intratherapeutics, Inc.
St. Paul, MN 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
IVC venous clip (Teflon)
coil, stent, filter
Pilling Weck Co. 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Jostent
316L SS
coil, stent, filter
Jomed
Helsingborg, Sweden 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
LGM IVC filter (Phynox)
coil, stent, filter
B. Braun Vena Tech
Evanston, IL 
 Safe

1.5 

26. Kiproff PM, Deeb DL, Contractor FM, Khoury MB. Magnetic resonance characteristics of the LGM vena cava filter: technical note. Cardiovasc Intervent Radiol 1991;14:254-255.  Coils, Filters, Stents, and Grafts 
LPS Stent, bifurcated
36 x 20 mm
nitinol
coil, stent, filter
World Medical Manufacturing Corp.
Sunrise, FL 
 Safe

1.5 

70. Shellock FG, Shellock VJ. MRI Safety of cardiovascular implants: evaluation of ferromagnetism, heating, and artifacts. Radiology 2000;214:P19H.  Coils, Filters, Stents, and Grafts 
LPS Thoracic Stent
46mm
nitinol
coil, stent, filter
World Medical Manufacturing Corp.
Sunrise, FL 
 Safe

1.5 

70. Shellock FG, Shellock VJ. MRI Safety of cardiovascular implants: evaluation of ferromagnetism, heating, and artifacts. Radiology 2000;214:P19H.  Coils, Filters, Stents, and Grafts 
MAC-Stent
17 x 3 mm
316L SS
coil, stent, filter
AMG
Munich, Germany 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Maas helical endovascular stent
coil, stent, filter
Medinvent
Lausanne, Switzerland 
 Safe

4.7 

21. Teitelbaum GP, Bradley WG, Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology 1988;166:657-664.  Coils, Filters, Stents, and Grafts 
Maas helical IVC filter
coil, stent, filter
Medinvent
Lausanne, Switzerland 
 Safe

4.7 

21. Teitelbaum GP, Bradley WG, Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology 1988;166:657-664.  Coils, Filters, Stents, and Grafts 
Magic Wallstent
platinum and cobalt-alloy
coil, stent, filter
Schneider
Bulach, Switzerland 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
Micro Stent II
24 x 3.0 mm
316L SS
coil, stent, filter
Medtronic AVE
Minneapolis, MN 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Mini-Crown Stent
316L SS
coil, stent, filter
Cordis
Miami, FL 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
Mobin-Uddin IVC/umbrella filter
coil, stent, filter
American Edwards
Santa Ana, CA 
 Safe

4.7 

21. Teitelbaum GP, Bradley WG, Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology 1988;166:657-664.  Coils, Filters, Stents, and Grafts 
Multi-Link Stent
316L SS
coil, stent, filter
Guidant
Santa Clara, CA 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
Gianturco-Roubin II
GR 2
20 x 3.0 mm
316L SS
coil, stent, filter
Cook Medical, www.cookmedical.com 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Gianturco-Roubin Stent
Flex-Stent
316L SS
coil, stent, filter
Cook Medical, www.cookmedical.com  
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
Gore TIPS Endoprosthesis
nitinol
coil, stent, filter
W.L. Gore and Associates, Inc.
Flagstaff, AZ 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Greenfield Vena Cava Filter (316L SS)
Boston Scientific, www.bostonscientific.com 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Greenfield vena cava filter (titanium alloy)
coil, stent, filter
Ormco
Glendora, CA 
 Safe

1.5 

21. Teitelbaum GP, Bradley WG, Klein BD. MR imaging artifacts, ferromagnetism, and magnetic torque of intravascular filters, stents, and coils. Radiology 1988;166:657-664.  Coils, Filters, Stents, and Grafts 
Palmaz endovascular stent
coil, stent, filter
Johnson & Johnson Interventional
Warren, NJ 
 Safe

1.5 

  Coils, Filters, Stents, and Grafts 
Palmaz-Schatz Stent
15 x 3.0 mm
316L SS
Johnson and Johnson 
 Safe

1.5 

72. Hug J, Nagel E, Bornstedt A, Schackenburg B, Oswald H, Fleck E. Coronary arterial stents: safety and artifacts during MR imaging. Radiology 2000;216:781-787.  Coils, Filters, Stents, and Grafts 
Palmaz-Schatz Stent
P-S 153, 316L Cordis, Miami, FL 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 
Palmaz-Schatz Stent
P-S 154, 316L SS
Cordis 
 Safe

1.5 

69. Jost C, Kuman V. Are current cardiovascular stents MRI safe. J Invasive Cardiol 1998;10:477-479.  Coils, Filters, Stents, and Grafts 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net