Default.asp?T_MRI_DOC_LISTOrder=Sorter_strength&T_MRI_DOC_LISTDir=ASC&T_MRI_DOC_LISTPage=15
 mri_brain_scan
 Default.asp
 GenPg.asp?pgname=Disclaimer
 TheList_search.asp
 SafetyInfog.asp
 GenPg.asp?pgname=ScreeningForm
 GenPg.asp?pgname=ProductTesting
 GenPg.asp?pgname=OrderingBooks
 GenPg.asp?pgname=Lectures
 GenPg.asp?pgname=AboutDrShellock
 PriorityEmail.asp
 
 mri_brain_scan
 

Search THE LIST.   All parameters below are optional.  Click Search button.



     ALL (default) means search results will contain *ALL* words you type above.
                       Selecting ANY returns records having *ANY* words above. (more recs returned) 
   Result Status
Clear Search Fields Click Here for the Info and Terminology Page Regarding THE LIST    
Records: 4844                              Click Here for Search HELP  
Per page:   First Prev   11 12 13 14 15 16 17 18 19 20 of  162  Next Last                                    
Object Status Strength Ascending Reference Safety Info
Perfix interence screw (17-4 SS)
orthopedic implant
Instrument Makar
Okemos, MI 
 Conditional 5

1.5 

34. Shellock FG, Mink JH, Curtin S, et al. MRI and orthopedic implants used for anterior cruciate ligament reconstruction: assessment of ferromagnetism and artifacts. J Magn Reson Imaging 1992;2:225-228.  Orthopedic Implants, Materials, and Devices 
Rusch Rod
orthopedic implant 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 
Side plate, 6-hole (titanium alloy)
orthopedic implant
DePuy ACE Co.
El Segundo, CA 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 
Spinal L-Rod
orthopedic implant
DePuy
Warsaw, IN 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 
Stainless steel mesh
orthopedic implant
Zimmer
Warsaw, IN 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Orthopedic Implants, Materials, and Devices 
Stainless steel plate
orthopedic implant
Zimmer
Warsaw, IN 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Orthopedic Implants, Materials, and Devices 
Stainless steel screw
orthopedic implant
Zimmer
Warsaw, IN 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Orthopedic Implants, Materials, and Devices 
Stainless steel wire
orthopedic implant
Zimmer
Warsaw, IN 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Orthopedic Implants, Materials, and Devices 
Staple plate, large (Zimaloy)
orthopedic implant
Zimmer
Warsaw, IN 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Orthopedic Implants, Materials, and Devices 
Synthes AO DCP 2, 3, 4, 5 hole plate
orthopedic implant 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 
Tibial nail, 9 mm (titanium alloy)
orthopedic implant
DePuy ACE Medical Co.
El Segundo, CA 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 
Universal Reconstruction Ribbon (titanium)
orthopedic implant
DePuy ACE Medical Co.
El Segundo, CA 
 Safe

1.5 

  Orthopedic Implants, Materials, and Devices 
Richards Teflon piston (Teflon)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

38. Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-804.  Otologic Implants 
Robinson incus replacement prosthesis
(ASTM-318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Robinson stapes prosthesis
(ASTM-318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Robinson-Moon offset
stapes prosthesis (ASTM-318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Robinson-Moon-Lippy offset
stapes prosthesis (ASTM- 318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Ronis piston stapes prosthesis
(316L SS, fluoroplastic)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Shea cup piston stapes prosthesis
(platinum, fluoroplastic)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Shea malleus attachment piston (Teflon)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

38. Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-804.  Otologic Implants 
Shea stainless steel
and Teflon wire prosthesis (Teflon, 316 L SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

38. Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-804.  Otologic Implants 
Scheer piston (Teflon, 316L SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

33. Lyons CJ, Betz RR, Mesgarzadeh M, et al. The effect of magnetic resonance imaging on metal spine implants. Spine 1989;14:670-672.  Otologic Implants 
Scheer piston stapes prosthesis
(316L SS, fluoroplastic)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Schuknecht gelfoam and wire
prosthesis, Armstrong style (316L SS)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

40. Leon JA, Gabriele OF. Middle ear prothesis: significance in magnetic resonance imaging. Magn Reson Imaging 1987;5:405-406.  Otologic Implants 
Schuknecht piston stapes prosthesis
(316L SS, fluoroplastic)
otologic implant
Richards Medical Co.
Memphis, TN 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Schuknecht Tef-wire incus attachment
(ASTM-318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Schuknecht Tef-wire malleus attachment
(ASTM-318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 
Schuknecht Teflon wire piston
0.6 mm (Teflon, 316L SS)
otologic implant Richards Medical Co.
Memphis, TN 
 Safe

1.5 

38. Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-804.  Otologic Implants 
Schuknecht Teflon wire piston
0.8 mm (Teflon, 316L SS)
otologic implant Richards Medical Co.
Memphis, TN 
 Safe

1.5 

38. Applebaum EL, Valvassori GE. Further studies on the effects of magnetic resonance fields on middle ear implants. Ann Otol Rhinol Laryngol 1990;99:801-804.  Otologic Implants 
Sheehy incus replacement
(ASTM-318-76 Grade 2 SS)
otologic implant
Storz
St. Louis, MO 
 Safe

1.5 

35. Shellock FG, Schatz CJ. High-field strength MR imaging and metallic otologic implants. Am J Neuroradiol 1991;12:279-281.  Otologic Implants 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net
Be sure to read our Disclaimer.