Default.asp?T_MRI_DOC_LISTPage=19
 mri_brain_scan
 Default.asp
 GenPg.asp?pgname=Disclaimer
 TheList_search.asp
 SafetyInfog.asp
 GenPg.asp?pgname=ScreeningForm
 GenPg.asp?pgname=ProductTesting
 GenPg.asp?pgname=OrderingBooks
 GenPg.asp?pgname=Lectures
 GenPg.asp?pgname=AboutDrShellock
 PriorityEmail.asp
 
 mri_brain_scan
 

Search THE LIST.   All parameters below are optional.  Click Search button.



     ALL (default) means search results will contain *ALL* words you type above.
                       Selecting ANY returns records having *ANY* words above. (more recs returned) 
   Result Status
Clear Search Fields Click Here for the Info and Terminology Page Regarding THE LIST    
Records: 4844                              Click Here for Search HELP  
Per page:   First Prev   15 16 17 18 19 20 21 22 23 24 of  162  Next Last                                    
Object Status Strength Reference Safety Info
Biosymetric P.P. (Finger) Fixator
external fixation device
316 SS, carbon composite
Biomet, Inc.
Warsaw, Indiana 
 Conditional 5

  External Fixation Devices 
BioTREK
PFO closure device
NMT Medical
Boston, MA 
 Conditional 6

  Patent Ductus Arteriosus (PDA), Atrial Septal Defect (ASD), Ventricular Septal Defect (VSD) Occluders, and Patent Foramen Ovale Closure Devices 
Biotronik Cardiac Implantable Cardioverter Defibrillator (ICD)
List of MR Conditional Versions
Biotronik, www.biotronikusa.com/manuals/index.cfm NOTE: Certain devices are MR Conditional at 1.5 T and others are MR Conditional at 1.5 and 3T. Refer to the specific type and model by visiting the website provided above.  
 Conditional 5

1.5, 3 

  Cardiac Pacemakers, Implantable Cardioverter Defibrillators (ICDs), and Cardiac Monitors 
Biotronik Cardiac Implantable Cardioverter Defibrillator (ICD)
List of MR Conditional Versions
Biotronik, www.biotronikusa.com/manuals/index.cfm NOTE: Certain devices are MR Conditional at 1.5 T and others are MR Conditional at 1.5 and 3T. Refer to the specific type and model by visiting the website provided above.  
 Conditional 5

1.5, 3 

  Cardiac Pacemakers, Implantable Cardioverter Defibrillators (ICDs), and Cardiac Monitors 
Biotronik Cardiac Pacemaker
List of MR Conditional Versions
Biotronik, www.biotronikusa.com/manuals/index.cfm NOTE: Certain devices are MR Conditional at 1.5 T and others are MR Conditional at 1.5 and 3T. Refer to the specific type and model by visiting the website provided above.  
 Conditional 5

1.5, 3 

  Cardiac Pacemakers, Implantable Cardioverter Defibrillators (ICDs), and Cardiac Monitors 
Biotronik Cardiac Pacemaker
List of MR Conditional Versions
Biotronik, www.biotronikusa.com/manuals/index.cfm NOTE: Certain devices are MR Conditional at 1.5 T and others are MR Conditional at 1.5 and 3T. Refer to the specific type and model by visiting the website provided above.  
 Conditional 5

1.5 

  Cardiac Pacemakers, Implantable Cardioverter Defibrillators (ICDs), and Cardiac Monitors 
BioValsalva Porcine Aortic Valved Conduit
Vascutech and Terumo Medical Corporation, www.terumomedical.com 
 Safe

1.5 

  Miscellaneous Implants and Devices 
BioZorb Tissue Marker
Focal Therapeutics, www.focaltherapeutics.com 
 Conditional 5

  Biopsy Needles, Markers, and Devices 
Bipolar Coagulation Forceps for
Use in Intraoperative MRI Systems
Aesculap AG & CO.KG
Tuttlingen, Germany 
 Safe

3.0 

83. Shellock FG. Biomedical implants and devices: assessment of magnetic field interactions with a 3.0-Tesla MR system. J Magn Reson Imaging 2002;16:721-732.  Surgical Instruments and Devices 
BIRMINGHAM Hip Resurfacing (BHR) System Implant
Smith & Nephew, www.smith-nephew.com  
 Conditional 5

1.5, 3 

  Orthopedic Implants, Materials, and Devices 
Bjork Shiley Monostrut
Aortic
Model ABMS
chromium cobalt alloy
heart valve
Pfizer, Inc.
Cincinnati, OH 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Bjork Shiley Monostrut
Mitral
Model MBRMS
chromium cobalt alloy
heart valve
Pfizer, Inc.
Cincinnati, OH 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Bjork Shiley Monostrut
Mitral
Model MBUM
chromium cobalt alloy
heart valve
Pfizer, Inc.
Cincinnati, OH 
 Conditional 5

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Bjork Shiley
Pyrolitic Carbon Conical Disc
Mitral
Model MBRP
chromium cobalt alloy
heart valve
Pfizer, Inc.
Cincinnati, OH 
 Conditional 5

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Bjork Shiley
Pyrolitic Carbon Conical Disc
Mitral
Model MBUP
chromium cobalt alloy
heart valve
Pfizer, Inc.
Cincinnati, OH 
 Safe

1.5 

75. Edwards, M-B, Taylor KM, Shellock FG. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 Tesla. J Magn Reson Imag 2000;12:363-369.  Heart Valves and Annuloplasty Rings 
Bjork-Shiley (convexo/concave)
heart valve
Shiley Inc.
Irvine, CA 
 Safe

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Heart Valves and Annuloplasty Rings 
Bjork-Shiley (universal/spherical)
heart valve
Shiley Inc.
Irvine, CA 
 Conditional 5

1.5 

3. Shellock FG, Crues JV. High-field strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces. Am J Roentgenol 1988;151:389-392.  Heart Valves and Annuloplasty Rings 
Bjork-Shiley, Model 22 MBRC 11030
Heart Valve
Shiley Inc.
Irvine, CA 
 Conditional 5

1.5 

18. Shellock FG, Morisoli SM. Ex vivo evaluation of ferromagnetism, heating, and artifacts for heart valve prostheses exposed to a 1.5 Tesla MR system. J Magn Reson Imaging 1994;4:756-758.  Heart Valves and Annuloplasty Rings 
Bjork-Shiley, Model MBC
Heart Valve
Shiley Inc.
Irvine, CA 
 Conditional 5

1.5 

18. Shellock FG, Morisoli SM. Ex vivo evaluation of ferromagnetism, heating, and artifacts for heart valve prostheses exposed to a 1.5 Tesla MR system. J Magn Reson Imaging 1994;4:756-758.  Heart Valves and Annuloplasty Rings 
Black Oval
Gyrus ACMI (Olympus Medical), www.medical.olympusamerica.com  
 Safe

1.5, 3 

  Otologic Implants 
Black Silicone Filiform Double Pigtail Ureteral Stent
Cook Urological, www.cookmedical.com 
 Conditional 6

  Coils, Filters, Stents, and Grafts 
Blazer Stent
OrbusNeich
www.orbusneich.com 
 Conditional 6

  Coils, Filters, Stents, and Grafts 
Blip Implanted Fiducial Marker
Platinum/Iridium
Navotek Medical Ltd.
Yokneam, Israel 
 Conditional 6

  Miscellaneous Implants and Devices 
Blockade Medical Barricade Coil System
embolization coil
Blockade Medical, blockademedical.com 
 Conditional 6

  Coils, Filters, Stents, and Grafts 
Blom-Singer Adjustable Bi-Flanged Fistula Prosthesis
InHealth Technologies, www.inhealth.com  
 Safe

1.5, 3 

  Miscellaneous Implants and Devices 
Blom-Singer Advantage Indwelling Voice Prosthesis
Hard Valve Assembly
InHealth Technologies, www.inhealth.com 
 Conditional 8

1.5, 3 

  Miscellaneous Implants and Devices 
Blom-Singer Advantage Indwelling Voice Prosthesis
Soft Valve Assembly
InHealth Technologies, www.inhealth.com 
 Conditional 8

1.5, 3 

  Miscellaneous Implants and Devices 
Blom-Singer Classic Indwelling Voice Prosthesis
InHealth Technologies, www.inhealth.com 
 Safe

1.5, 3 

   
Blom-Singer ClassicFlow HME for Tracheostomy
InHealth Technologies, www.inhealth.com 
 Safe

1.5, 3 

  Miscellaneous Implants and Devices 
Blom-Singer Dual Valve Indwelling Voice Prosthesis
InHealth Technologies, www.inhealth.com 
 Conditional 8

1.5, 3 

  Miscellaneous Implants and Devices 

_____________________________________________________________________________________
  (c) 2017 by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. All Rights Reserved. All copyrights and pertinent trademarks are owned by Shellock R & D Services, Inc. and Frank G. Shellock, Ph.D. No part of the MRISAFETY.COM web site may be reproduced, stored in any retrieval system, or transmitted in any form or by any means, physical, electronic or otherwise, without the prior written permission of Shellock R & D Services, Inc. or Frank G. Shellock, Ph. D. Request for permission to reproduce any information contained on the MRISAFETY.COM web site should be addressed to: frank.shellock@gte.net
Be sure to read our Disclaimer.